<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Biochemistry &#8211; Eaxytest</title>
	<atom:link href="https://eaxytest.com/product-category/biochemistry/feed" rel="self" type="application/rss+xml" />
	<link>https://eaxytest.com</link>
	<description>To Make Medical Diagnostic Tests Easier</description>
	<lastBuildDate>Thu, 31 Mar 2022 12:44:20 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.6.2</generator>
	<item>
		<title>CH-10V POCT Biochemistry Analyzer</title>
		<link>https://eaxytest.com/product/ch-10v-poct-biochemistry-analyzer</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Mar 2022 04:40:02 +0000</pubDate>
				<guid isPermaLink="false">https://eaxytest.com/?post_type=product&#038;p=165</guid>

					<description><![CDATA[<strong>Technical Specificaions:</strong>
<ul>
 	<li>Varieties of lyophilized dish packages, suitable for personalized medical treatment</li>
 	<li>Instrument miniaturization, lyophilized reagent pre-packaged design,</li>
 	<li>convenient transportation</li>
 	<li>Quick detection, easy to operate</li>
 	<li>Whole blood detection, standard addition</li>
</ul>]]></description>
										<content:encoded><![CDATA[<p>CH-10 fully auto biochemistry analyzer is a very mini analyzer, but with full functions and various items for the biochemical diagnosis of small pets, and applicable across a wide range of species..</p>
<p><strong>Easy to use</strong></p>
<p>Just three steps to get results: Inject sample- Insert cartridge-Print results</p>
<p><strong>Accurate</strong></p>
<p>Accurate reference laboratory quality results – utilizes photometric colorimetric principle</p>
<p><strong>Fast</strong></p>
<p>7-15 Results in 15 minutes per sample</p>
<p><strong>Portable and Smart</strong></p>
<p>3kg, 27*18*15.5cm, Android touch screen and built-in thermal printer</p>
<p><strong>Maintenance Free</strong></p>
<p>lyophilized reagent pre-packaged design- no need internal pumps or valves</p>
<p>No maintenance contracts or consumables</p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-167" src="https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1.png" alt="" width="756" height="756" srcset="https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1.png 756w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-300x300.png 300w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-150x150.png 150w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-146x146.png 146w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-50x50.png 50w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-75x75.png 75w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-85x85.png 85w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-80x80.png 80w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-1-500x500.png 500w" sizes="(max-width: 756px) 100vw, 756px" /></p>
<p><strong>Specification：</strong></p>
<table>
<tbody>
<tr>
<td width="227">Test Principle</td>
<td width="619">Photoelectric colorimetry</td>
</tr>
<tr>
<td width="227"> Sample Types</td>
<td width="619">Anticoagulant whole blood, plasma, serum</td>
</tr>
<tr>
<td width="227">Transmission Interface</td>
<td width="619">On-line use of LIS system</td>
</tr>
<tr>
<td width="227">Barcode Recognition</td>
<td width="619">Automatic identification of two-dimensional code for reagent disc</td>
</tr>
<tr>
<td width="227">Reaction Temperature</td>
<td width="619">37±0.5℃</td>
</tr>
<tr>
<td width="227">Light Source</td>
<td width="619">LED</td>
</tr>
<tr>
<td width="227">Printer</td>
<td width="619">Built-in thermal printer, also available to external printer (with wireless printer drive)</td>
</tr>
<tr>
<td width="227">Operating System</td>
<td width="619">Android 5.1（5 inches）</td>
</tr>
<tr>
<td width="227">Memory Capacity</td>
<td width="619">1GB, with expandable 32GB TF card</td>
</tr>
<tr>
<td width="227">Size</td>
<td width="619"> 270mm*180mm*155mm</td>
</tr>
<tr>
<td width="227">Weight</td>
<td width="619">3kg</td>
</tr>
</tbody>
</table>
<p><strong>Operation:</strong></p>
<p><img decoding="async" class="alignnone size-full wp-image-166" src="https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyze.png" alt="" width="700" height="219" srcset="https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyze.png 700w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyze-300x94.png 300w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyze-260x81.png 260w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyze-50x16.png 50w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyze-150x47.png 150w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<p>Reagent Kits</p>
<table>
<tbody>
<tr>
<td width="228">Health Check Kit</td>
<td width="708">TP, ALB, *GLOB, TB, ALT, ALP, CK, AMY, Crea, UREA, TC, GLU, Ca, IP, *A/G,*BUN/Cr</td>
</tr>
<tr>
<td width="228">Liver Function Kit I</td>
<td width="708">TP, ALB, *GLOB, *A/G, TB, ALP, GGT,ALT, γ-GT, DB</td>
</tr>
<tr>
<td width="228">Liver Function Kit II</td>
<td width="708">TP, ALB, *GLOB, *A/G, TB, DB, TG, CHOL, GGT, ALT, γ-GT, NH3, CK, LDH, TBA, AST/ALT</td>
</tr>
<tr>
<td width="228">Renal Function Kit</td>
<td width="708">ALB, PHOS, UREA, *BUN/Cr, CO2, Crea, UA, Ca</td>
</tr>
<tr>
<td width="228">Electrolyte Kit I</td>
<td width="708">Cl-, PHOS, Mg, K+, Ca, Na+, CO2</td>
</tr>
<tr>
<td width="228">Electrolyte Kit II</td>
<td width="708">Cl-, PHOS, Mg, K+, Ca, Na+, CO2, PH</td>
</tr>
<tr>
<td width="228">Inflammation Kit</td>
<td width="708">CRP, Crea, UREA, BUN/Cr, AMY, LPS</td>
</tr>
<tr>
<td width="228">Preoperative<br />
Examination Kit I</td>
<td width="708">*TP, GGT, ALT, Crea, UREA, LDH, CK,GLU</p>
<p>&nbsp;</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td width="228">Preoperative<br />
Examination Kit II</td>
<td width="708">*TP, GGT, ALT, Crea, UREA, ALP, CK, GLU, Ratio</td>
</tr>
<tr>
<td width="228">ICU Kit</td>
<td width="708">ALT, Crea, UREA, K+, Na+, Cl-, CO2,GLU</td>
</tr>
<tr>
<td width="228">Pancreatic and Renal Function Kit (Dog)</td>
<td width="708">AMY, Crea, BUN, Cysc, CRP, LPS/CPL, BUN/CREA</td>
</tr>
<tr>
<td width="228">Kidney Test Kit</td>
<td width="708">K+, Na+, Cysc, Cl-, Ca, PHOS, NH3, LDH, ALB, LPS/CPL, BUN/CREA, AMY, Crea, BUN</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CH-24V Biochemistry Analyzer</title>
		<link>https://eaxytest.com/product/ch-24v-biochemistry-analyzer</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Mar 2022 04:26:52 +0000</pubDate>
				<guid isPermaLink="false">https://eaxytest.com/?post_type=product&#038;p=161</guid>

					<description><![CDATA[<strong>Technical Specificaions:</strong>

Innovative patented design, mini /easily operating fully-auto biochemical analyzer;Based mainstream direct-reading and post-spectroscopic technique;Use routine liquid reagent from any suppliers, volume only 300ul/test;With complete test menu and methods as big chemistry analyzerStandard and Accurate;

Test items can be combined freely;More economical, smaller and lower maintenance than a traditional fully-auto analyzer, but with main functions and easier to operate;

Test cost 300ul reagent, lower than normal photometers (500ul/test);Wider range of application, especially for low sample size users]]></description>
										<content:encoded><![CDATA[<p>CH-24V biochemistry analyzer with innovative and patented design, is a mini version of fully automatic biochemical analyzer. It’s very easy to use and just three steps to get the results. The items could be optional and flexible to combine.</p>
<p>&nbsp;</p>
<p><img decoding="async" class="alignnone size-full wp-image-162" src="https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer.png" alt="" width="1412" height="466" srcset="https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer.png 1412w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-300x99.png 300w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-1024x338.png 1024w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-768x253.png 768w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-260x86.png 260w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-50x17.png 50w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-150x50.png 150w, https://eaxytest.com/wp-content/uploads/2022/03/CH-24V-Biochemistry-Analyzer-800x264.png 800w" sizes="(max-width: 1412px) 100vw, 1412px" /></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>BS-3000V Semi Auto Biochemistry Analyzer</title>
		<link>https://eaxytest.com/product/bs-3000v-semi-auto-biochemistry-analyzer</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Mar 2022 04:24:47 +0000</pubDate>
				<guid isPermaLink="false">https://eaxytest.com/?post_type=product&#038;p=159</guid>

					<description><![CDATA[<strong>Technical Specificaions:</strong>

Reading Cuvette<strong>:</strong>  Flow through cell

Measuring Volume: 200ul-800ul

Incubator: 20 INCUBATING POSITIONS

Temperature Precision:±0.1℃

Method: End point, Fixed time, Multistandard,Differential, Bichromatic and Immunoturbidimetric, etc.

Quality Control: Excellent Q.C.function,Q.C.chart may be displayed and printed

Display: Back-illuminated LCD

Storage: Over 200 programs,1000 test results

Printer: Built-in thermal printer]]></description>
										<content:encoded><![CDATA[<p>BS3000V is an easy-to-use, accurate and compact semi-auto biochemistry analyzer. The analyzer is designed on the basis of Lambert-Beer Law. The main components include high quality quartz flow cell, touch screen and built-in incubator.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CH-10 POCT Biochemistry Analyzer</title>
		<link>https://eaxytest.com/product/ch-10-poct-biochemistry-analyzer</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Mar 2022 03:22:04 +0000</pubDate>
				<guid isPermaLink="false">https://eaxytest.com/?post_type=product&#038;p=155</guid>

					<description><![CDATA[<strong>Technical Specificaions:</strong>
<ul>
 	<li>Varieties of lyophilized dish packages, suitable for personalized medical treatment</li>
 	<li>Instrument miniaturization, lyophilized reagent pre-packaged design,</li>
 	<li>convenient transportation</li>
 	<li>Quick detection, easy to operate</li>
 	<li>Whole blood detection, standard addition</li>
</ul>]]></description>
										<content:encoded><![CDATA[<p>CH-10 fully auto biochemistry analyzer is a very mini analyzer, but with full functions and various items for the biochemical diagnosis of small clinic and lab.</p>
<p><strong>Easy to use</strong></p>
<p>Just three steps to get results: Inject sample- Insert cartridge-Print results</p>
<p><strong>Accurate</strong></p>
<p>Accurate reference laboratory quality results – utilizes photometric colorimetric principle</p>
<p><strong>Fast</strong></p>
<p>7-15 Results in 15 minutes per sample</p>
<p><strong>Portable and Smart</strong></p>
<p>3kg, 27*18*15.5cm, Android touch screen and built-in thermal printer</p>
<p><strong>Maintenance Free</strong></p>
<p>lyophilized reagent pre-packaged design- no need internal pumps or valves</p>
<p>No maintenance contracts or consumables</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<table>
<tbody>
<tr>
<td width="227">Test Principle</td>
<td width="619">Photoelectric colorimetry</td>
</tr>
<tr>
<td width="227"> Sample Types</td>
<td width="619">Anticoagulant whole blood, plasma, serum</td>
</tr>
<tr>
<td width="227">Transmission Interface</td>
<td width="619">On-line use of LIS system</td>
</tr>
<tr>
<td width="227">Barcode Recognition</td>
<td width="619">Automatic identification of two-dimensional code for reagent disc</td>
</tr>
<tr>
<td width="227">Reaction Temperature</td>
<td width="619">37±0.5℃</td>
</tr>
<tr>
<td width="227"> Light Source</td>
<td width="619">LED</td>
</tr>
<tr>
<td width="227"> Printer</td>
<td width="619">Built-in thermal printer, also available to external printer (with wireless printer drive)</td>
</tr>
<tr>
<td width="227"> Operating System</td>
<td width="619">Android 5.1（5 inches）</td>
</tr>
<tr>
<td width="227"> Memory Capacity</td>
<td width="619">1GB, with expandable 32GB TF card</td>
</tr>
<tr>
<td width="227"> Size</td>
<td width="619"> 270mm*180mm*155mm</td>
</tr>
<tr>
<td width="227"> Weight</td>
<td width="619">3kg</td>
</tr>
</tbody>
</table>
<p><strong> </strong></p>
<p><strong>Operation:</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-full wp-image-157" src="https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer.png" alt="" width="700" height="219" srcset="https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer.png 700w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-300x94.png 300w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-260x81.png 260w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-50x16.png 50w, https://eaxytest.com/wp-content/uploads/2022/03/POCT-Biochemistry-Analyzer-150x47.png 150w" sizes="(max-width: 700px) 100vw, 700px" /></p>
<p>Reagent Kits</p>
<table>
<tbody>
<tr>
<td width="228">Health Check Kit</td>
<td width="708">TP, ALB, *GLOB, TB, ALT, ALP, CK, AMY, Crea, UREA, TC, GLU, Ca, IP, *A/G,*BUN/Cr</td>
</tr>
<tr>
<td width="228">Liver Function Kit I</td>
<td width="708">TP, ALB, *GLOB, *A/G, TB, ALP, GGT,ALT, γ-GT, DB</td>
</tr>
<tr>
<td width="228">Liver Function Kit II</td>
<td width="708">TP, ALB, *GLOB, *A/G, TB, DB, TG, CHOL, GGT, ALT, γ-GT, NH3, CK, LDH, TBA, AST/ALT</td>
</tr>
<tr>
<td width="228">Renal Function Kit</td>
<td width="708">ALB, PHOS, UREA, *BUN/Cr, CO2, Crea, UA, Ca</td>
</tr>
<tr>
<td width="228">Electrolyte Kit I</td>
<td width="708">Cl-, PHOS, Mg, K+, Ca, Na+, CO2</td>
</tr>
<tr>
<td width="228">Electrolyte Kit II</td>
<td width="708">Cl-, PHOS, Mg, K+, Ca, Na+, CO2, PH</td>
</tr>
<tr>
<td width="228">Inflammation Kit</td>
<td width="708">CRP, Crea, UREA, BUN/Cr, AMY, LPS</td>
</tr>
<tr>
<td width="228">Preoperative<br />
Examination Kit I</td>
<td width="708">*TP, GGT, ALT, Crea, UREA, LDH, CK,GLU</p>
<p>&nbsp;</td>
</tr>
</tbody>
</table>
<table>
<tbody>
<tr>
<td width="228">Preoperative<br />
Examination Kit II</td>
<td width="708">*TP, GGT, ALT, Crea, UREA, ALP, CK, GLU, Ratio</td>
</tr>
<tr>
<td width="228">ICU Kit</td>
<td width="708">ALT, Crea, UREA, K+, Na+, Cl-, CO2,GLU</td>
</tr>
<tr>
<td width="228">Kidney Test Kit</td>
<td width="708">K+, Na+, Cysc, Cl-, Ca, PHOS, NH3, LDH, ALB, LPS/CPL, BUN/CREA, AMY, Crea, BUN</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>CH-24 Biochemistry Analyzer</title>
		<link>https://eaxytest.com/product/ch-24-biochemistry-analyzer</link>
					<comments>https://eaxytest.com/product/ch-24-biochemistry-analyzer#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sat, 26 Mar 2022 02:44:50 +0000</pubDate>
				<guid isPermaLink="false">https://eaxytest.com/?post_type=product&#038;p=139</guid>

					<description><![CDATA[<strong>Technical Specificaions:</strong>

Innovative patented design, mini /easily operating fully-auto biochemical analyzer;Based mainstream direct-reading and post-spectroscopic technique;Use routine liquid reagent from any suppliers, volume only 300ul/test;With complete test menu and methods as big chemistry analyzerStandard and Accurate;

Test items can be combined freely;More economical, smaller and lower maintenance than a traditional fully-auto analyzer, but with main functions and easier to operate;

Test cost 300ul reagent, lower than normal photometers (500ul/test);Wider range of application, especially for low sample size users]]></description>
										<content:encoded><![CDATA[<p>CH-24 biochemistry analyzer with innovative and patented design, is a mini version of fully automatic biochemical analyzer. It’s very easy to use and just three steps to get the results. The items could be optional and flexible to combine.</p>
<p><strong>Operation steps</strong></p>
<p><img loading="lazy" decoding="async" class="alignnone size-medium wp-image-141" src="https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-300x99.png" alt="" width="300" height="99" srcset="https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-300x99.png 300w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-1024x338.png 1024w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-768x253.png 768w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-260x86.png 260w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-50x17.png 50w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-150x50.png 150w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps-800x264.png 800w, https://eaxytest.com/wp-content/uploads/2022/03/Operation-steps.png 1412w" sizes="(max-width: 300px) 100vw, 300px" /></p>
]]></content:encoded>
					
					<wfw:commentRss>https://eaxytest.com/product/ch-24-biochemistry-analyzer/feed</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>BS3000 Semi Auto Biochemistry Analyzer</title>
		<link>https://eaxytest.com/product/bs3000-semi-auto-biochemistry-analyzer</link>
					<comments>https://eaxytest.com/product/bs3000-semi-auto-biochemistry-analyzer#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Fri, 25 Mar 2022 06:35:07 +0000</pubDate>
				<guid isPermaLink="false">http://tes.rogss.com/?post_type=product&#038;p=125</guid>

					<description><![CDATA[Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

<strong>Features:</strong>

Color touch screen

20 incubation positions, 3 timer

Flow cell system

7 wavelength, 340/405/492/510/546/578/620, 2 more wavelength on request

Built-in thermal printer, print test result automatically

Long life of Halogen lamp source adopting

Free green software to connect PC by USB]]></description>
										<content:encoded><![CDATA[<p><strong>Technical Specifications:</strong></p>
<p>Reading Cuvette<strong>:</strong>  Flow through cell</p>
<p>Measuring Volume: 200ul-800ul</p>
<p>Incubator: 20 INCUBATING POSITIONS</p>
<p>Temperature Precision:±0.1℃</p>
<p>Method: End point, Fixed time, Multistandard,Differential, Bichromatic and Immunoturbidimetric, etc.</p>
<p>Quality Control: Excellent Q.C.function,Q.C.chart may be displayed and printed</p>
<p>Display: Back-illuminated LCD</p>
<p>Storage: Over 200 programs,1000 test results</p>
<p>Printer: Built-in thermal printer</p>
]]></content:encoded>
					
					<wfw:commentRss>https://eaxytest.com/product/bs3000-semi-auto-biochemistry-analyzer/feed</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
